Distribution transformer with amophous coil low loss
Threephaseamorphouscoil distributiontransformerwithStandardFullcompliedwithIEC6007…
Distribution transformer with amophous coil low loss

Distribution transformer with amophous coil low loss

Detailed description

  • Description
  • Ambient temperature:
  • Technical data

Three phase amorphous coil distribution transformer with 

Standard

Full complied with  IEC60076,GB1094-1996 

Amorphous alloy Material Introduction 

Amorphous alloy material is a low-loss transformer, using a novel energy-saving material . Amorphous alloy strip with iron as the basic elements tighter with silicon and other elements .

Under certain conditions melting using ultra rapid cooling technique and spraying it directly into the cooling 

rollers to cast thin . 

Amorphous alloy material characteristics 

(1) Material is thin , the thickness only 0.025mm, 1/10 of silicon steel 

(2) High resistivity is about three times as the silicon steel belt 

(3) Non- directional of crystalline arrangement 

(4) High frequency usually a few thousand Hertz 

(5) Iron loss is small at 1.35T, the loss is only 0.21W/kg ,65% smaller than ordinary silicon steel 

Transformer special service condition

The height above sea level is above 1000m;


Product Description

Three phase oil immersed electrical transformer rated voltage during 6-35kV, oil immersed transformer are most used in power plant, power grid transmission and distribution station,

 industry& commerce electrical substation as the electrical equipment of power transmission,

1. Rated voltage:6.3kV,10kV,11kV,13.2kV,13.8kV,15kV, 20KV, 22KV, 33KV,35KV

2. Rated power:5kva~25000kva

3, Two windings or three windings 

4, On-load or no-load voltage tapping changer 

5. Frequency:50HZ /60HZ

6. Vector group:Dyn11, Yyn0, Ynd11, or others

7. Cooling:ONAN/ ONAF/ OFAF

8. Tap changer:3 levels; 5 levels; 7 levels; 13 levels; 17 levels

9. Rating plate:Yes (Rockwell brand or Customer brand)

10. Corrugated refrigeration panels: Yes ( Four sides of the transformer shell)

11. Parts:

1)Oil draining valve 2)Oil level indicator 3)Thermometer  

 

Highest air temperature +40℃;

Lowest air temperature -45℃;(defines in detail when placing an order)

Transformer normal service condition

The height above sea level is below 1000m;

Ambient temperature:

Highest air temperature +40℃;

Highest daily average air temperature+30℃;

Highest annual average air temperature+20℃;

Lowest outdoor air temperature-25℃.

Rated Capacity (KVA)

Voltage combination

Connection

Symbol

load loss (W)

No-load loss(w) 75

No-load

Current %

Shirt-circuit Impedance

%

HV (kv)

LV (kv)

30

6

6.3

10

10.5

11

 

0.4

Yyn0

Dyn11

100

600

2.1

 4

50

130

870

2

63

150

1040

1.9

80

180

1250

1.8

100

200

1500

1.6

125

240

1800

1.5

160

270

2200

1.4

200

330

2600

1.3

250

400

3050

1.2

315

480

3650

1.1

400

570

4300

1

500

680

5100

1

630

810

6200

0.9

 4.5

800

980

7500

0.8

1000

1150

10300

0.7

          1250

1360

12000

0.6

          1600

1640

14500

0.6

          2000

1960

18000

0.5

Note: we can design and manufacture special transformer as customers' requirements.

Ordering Instruction:

1.product model;

2.rated capacity;

3.voltage range;

4.regulation range;

5.frequency;

6.connection symbol;

7. technical requirements for special transformer.

 

Best solution for your power!