Three phase pad mounted transformersRockwell transformer Co.,Ltd. offer an environ…
Detailed description
- Description
Three phase pad mounted transformers
Rockwell transformer Co.,Ltd. offer an environmentally responsible, high efficiency, safer choice. The units have high-fire-point fluid, providing fire safety benefits, and a projected life well beyond that of a traditional mineral-oil transformer. These efficient and cost-effective transformers use Envirotemp™ FR3™ fluid. Envirotran transformers are manufactured in 50 - 10,000kVA, in primary voltage classes of 11kV,15 kV, 25 kV and 35 kV.
kVA
50-20,000
Primary Voltage
Up to 34,500 V
Secondary Voltage
208-14,400 V
Environmental InformationThree-phase, pad-mounted transformers, for use on underground power distribution systems, are best suited for commercial applications in public access areas and where underground service is required. These transformers meet modern design requirements for flexibility and provide a visually pleasing installation. Construction allows installation in locations accessible to the general public without the need for protective fencing or vaults. These units are ideally suited for apartment buildings, schools, hospitals, shopping centers, commercial buildings, or industrial sites.
-Sealed tank construction
-Special waste disposal considerations
-Insulation temperature limit: 120 °C
-Temperature rise: 65 °C (standard); 55 °C or 55/65 °C (optional)
Special Design Options
-Special sound requirements
-Special altitude requirements
-Retrofit designs
-Higher efficiency requirements
-Special ambient conditions
Applicable Standards
-IEEE C57.12.00—Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
-IEEE C57.12.34—Requirements for Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers, 2,500 kVA and Smaller: High Voltage, 34,500 GrdY/ 19,920 V and Below; Low Voltage, 480 V and Below
-IEEE C57.12.28—Standard for Pad-Mounted Equipment—Enclosure Integrity
-IEEE C57.12.70—Standard for Terminal Markings and Connections for Distribution and Power Transformers
-IEEE C57.12.80—Standard Terminology for Power and Distribution Transformers
-IEEE C57.12.90—Standard Test Code for Liquid-Immersed Distribution, Short-Circuit Testing of Distribution and Power Transformers
-IEEE C57.13—Requirements for Instrument Transformers
-ANSI/IEEE 386—Separable Insulated Connector Systems for Power Distribution Systems Above 600 V
-ASTM D877—Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes
-NEMA AB1—Molded Case Circuit Breakers
-NEMA TR1—Transformers, Regulators, and Reactors
- Compact Substation
- Pad mounted transformer
- Prefabricated transformer substa...
- 12/24/36kV Cable branch box with switchgear inside
- YB -11/0.4kV EU style compact transformer
- YB -15/0.4kV EU style compact substation
- YB -22/0.4kV EU style compact substation
- YB- 30/0.4kV EU style compact transformer
- YB-33/0.4kV EU style compact substation
- 34.5kV 0.415kV compact substation 1600kVA kiosk substation
- 11/0.4kV 800kVA Mining substation
- 33kV 2500kVA pad mounted transformer
- 30/0.4kV 1000kVA substation 2500kVA Container transformer substation
- 11kV 15kV 20kV 22kV 30kV 33kV compact substation from China Professional manufacturer
- Outdoor prefabricated transformer substation
- Prefabricated switchgear substation