Indoor SF6 load break switch RLS-24B

General:
RLS-24B an indoor high-voltage SF6 load switch, an switchgear with the rated voltage of 12kV/24kV, adopted with SF6 gas as an arc-extinguishing and insulation medium, including thethree contactors for switching-on and switching-off andto-ground, and is characteristic in its small volume, its convenient installation and operation and itsthe great adaptability with surroundings.
RLS-24 of an indoor high-voltage SF6 load switch and RLS-12/24B of SF6 load switch plus fuse combination canfunctionto protect and controlthe electric equipmentsfor power supply and transformer substations especially being suitable for ring net cabinet, cable branch cabinet and distribution switching substation.
RLS-24 of an indoor high-voltage SF6 load switch and RLS-24B load switch plusfuse combination are complied withthe standards of GB3804-1990, IEC60256-1,1997, GB16926, IEC60420 etc..


Service environment:
a) Airtemperature
Maximumtemperature: +40℃; Minimumtemperature:-5℃
b) Humidity:  Monthly average humidity 95%; Daily average humidity 90%.
c) Altitude above sea level    Maximum installation altitude: 2500m
d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
e) Nofrequent violent shake



Note: For short circuit breaking and peak current isbased on Fuseplus combination.

No

Item

Unit

Parameter

1

Rated voltage

kV

12/24

2

Rated frequency

Hz

50/60

3

Rated current

A

630/800

4

wet

1min Power frequency  withstand voltage
dry

kV

38/50

48/60

5

Lightning impulse withstand voltage

kV

75/125

6

Rated short circuit breaking current (peak)

kA

Depend on CB & Fuse

7

Rated activeload and close circuit breaking current

A

630

8

Rated transferring current

A

1700/1400

9

Rated short circuit making current (peak)

kA

40

10

Rated cable(line) charging breaking current

A

50 and 10

1 1

Cable charge breaking current in earthing fault

A

20

12

Rated withstand current (peak)

kA

40

13

Short time withstand current (2s)

kA

31.5

14

Mechanism life

times

5000

Matching dimension of SF6 load break switch-fuse combination Fig 1) SF6 load break switch without upper cubicle

Outline dimension & installation sizes

Matters need attention

It is NOT allowed to disassembly the self-sealed valve in front of switch( connecting end of meter).

It is NOT allowed to unload the seal screws on switch at any time.
Ordering Instructions
Ordering instructions:
1. Belowing terms should be marked while ordering:
Model number, product name and quantity.
Model of operating mechanism.
Provide the rated voltage specification if motorization operating is required.
For load break switch + fuse combination, fuse model and specification is required.
Other special requirements.
2. Documents with product from manufacturer:
Certificate of qualification.
Testing report for products.
Packing list.

Other technical documents.








Notice: All technical specification same as SC6. Except the installation sizes.

Tel: 0086-577-27869966, 27869968, 27869969
Fax: 0086-577-27869967
Add: No 1,Fazhan Road, Wengyang Industrial Zone,Yueqing,Zhejiang, 325604
E-mail: rockwill.sale@gmail.com(Sales) rockwill.tech@gmail.com(Technic)

About Us
Success References
Best solution for your power!
Copyright © 2018 Rockwill Electric Group Co.,Ltd. All Rights Reserved.