The 40kW/60kW/80kW DC EV charger is suitable for special urban charing stations,urban public charging stations,intercity highway charging stations and other occasions requiring DC quick charging,especially suitable for rapid deployment under site limitation.
Features of 40kW/60kW/80kW DC EV Charger
1. Intelligent Control
2. High Efficiency
-
Simultaneously charging with 2 outputs
-
40kW/60kW/80kW for quick charging
-
SiC technology for high efficiency
3. Secure and Safe
-
PTB certfied energy meter with accurate measurement
-
Compatible with the IEC standard for your requirements
-
Multiple protections for running safely
Specification |
Model |
RWDC-YZ-40kW/750V |
RWDC-YZ-60kW/750V |
RWDC-YZ-80kW/750V |
AC Nominal Input |
Phases / Lines |
3 phase + neutral + PE |
3 phase + neutral + PE |
3 phase + neutral + PE |
Voltage |
400 V |
400 V |
400 V |
Frequency |
50Hz/60Hz |
50Hz/60Hz |
50Hz/60Hz |
DC Nominal Output |
Voltage |
200~750V |
200~750V |
200~750V |
Current |
Max. 100A |
Max. 200A |
Max. 200A |
Power |
40kW |
60kW |
80kW |
Electrical Parameter |
Power Factor |
≧0.99 (50%~100% load) |
≧0.99 (50%~100% load) |
≧0.99 (50%~100% load) |
THD Value |
≦5% (50%~100% load) |
≦5% (50%~100% load) |
≦5% (50%~100% load) |
Stable Voltage Accuracy |
≦±0.5% |
≦±0.5% |
≦±0.5% |
Stable Current Accuracy |
≦±1% |
≦±1% |
≦±1% |
Efficiency |
Max. 95% |
Max. 95% |
Max. 95% |
Auxiliary Power |
12V or 24V |
12V or 24V |
12V or 24V |
Structure Design |
Housing Material |
Galvanized steel |
Galvanized steel |
Galvanized steel |
Installation Method |
Floor-stand |
Floor-stand |
Floor-stand |
Wall-mount Bracket |
NA |
NA |
NA |
Charging Outlet |
Two charging guns (CCS 2) |
Two charging guns (CCS 2) |
Two charging guns (CCS 2) |
Cable Length |
5M |
5M |
5M |
LED Indicator |
3 indicators |
3 indicators |
3 indicators |
LCD Screen |
Yes |
Yes |
Yes |
Emergency Stop Button |
Yes |
Yes |
Yes |
Startup Mode |
Plug-and-play/RFID Card/QR Code/App |
Plug-and-play/RFID Card/QR Code/App |
Plug-and-play/RFID Card/QR Code/App |
RFID Function |
Yes |
Yes |
Yes |
Communication |
Charger v.s. EV |
PLC (DIN 70121: 2014-12) |
PLC (DIN 70121: 2014-12) |
PLC (DIN 70121: 2014-12) |
EN-GATE v.s. Charger |
CAN |
CAN |
CAN |
EN-GATE v.s. Backend |
Ethernet/4G/WIFI |
Ethernet/4G/WIFI |
Ethernet/4G/WIFI |
Communication Protocol |
OCPP 1.6 (JSON) |
OCPP 1.6 (JSON) |
OCPP 1.6 (JSON) |
Environment |
Operating Temperature |
-30 °C ~ +50 °C |
-30 °C ~ +50 °C |
-30 °C ~ +50 °C |
Working Humidity |
5%~95% without condensation |
5%~95% without condensation |
5%~95% without condensation |
Working Altitude |
<2000M |
<2000M |
<2000M |
Protection Grade |
IP54 |
IP54 |
IP54 |
Application Site |
Indoor/Outdoor |
Indoor/Outdoor |
Indoor/Outdoor |
Cooling Method |
Fan cooling |
Fan cooling |
Fan cooling |
Noise |
≦60dB |
≦60dB |
≦60dB |
Safety |
Multiple Protection |
Over/Under voltage protection, Overload protection, Short circuit protection, Over/Under temperature protection, Grounding protection, Surge protection |
Over/Under voltage protection, Overload protection, Short circuit protection, Over/Under temperature protection, Grounding protection, Surge protection |
Over/Under voltage protection, Overload protection, Short circuit protection, Over/Under temperature protection, Grounding protection, Surge protection |
MTBF |
100,000 hours |
100,000 hours |
100,000 hours |
Safety Standard |
IEC 61851-1:2017, IEC 61851-23:2014 |
IEC 61851-1:2017, IEC 61851-23:2014 |
IEC 61851-1:2017, IEC 61851-23:2014 |
Warranty |
1 years |
1 years |
1 years |
Package Information |
Product Dimension |
1600*750*430MM |
1600*750*430MM |
1600*750*430MM |
External Packing |
Wooden case |
Wooden case |
Wooden case |