The 60kW-160kW DC fast charging station is provided by Rockwill Energy Technology Co., Ltd. which is a R & D manufacturing and service-oriented High-technology enterprise focusing on providing overall power automation solutions and new energy electric vehicle applications. Rockwill Energy Technologies Ltd., as a joint venture with Chongqing Semi-conductor High-tech Institute, has worked around developing green, low-carbon, environmentally friendly products and services.
We support different cooperation ways like customization, supplying components, providing whole solutions, etc. We are now looking for great partners around the world for exploring a new career. Please feel free to contact us!
Main Features
• Charging up to 80% within 30 minutes
• Supporting CHAdeMO, GB/T 20234.1,3, CCS1 combo, CCS2 combo
• PF>0.99 (APFC)
• Efficiency>95% at nominal output power
• OCPP1.6 JSON
• Intelligent RFID card reader, ISO14443A (M1/MIFARE Card)
• 7” touch screen and friendly HMI interface support
• Supporting English, French, Spanish, and Russian
• Ethernet/4G/3G support
• IK10, IP54 class
• Easy installation and maintenance
Model Name |
80/120/160(1000vdc)
60/120/150(750vdc)
|
AC Input |
Input Rating |
Three phase |
Input Voltage |
400Vac ± 15% |
AC Input Connection |
3P + N + PE |
Max. Input Current (A) |
110 / 146 / 220 / 275 / 293 |
Frequency (Hz) |
45~65 |
Power Factor |
>0.99 @ 50% or higher load
|
DC Output |
Output Voltage Range |
50~500Vdc (CHAdeMO)
150~750Vdc (CCS) with 15kW module
150~1000Vdc (CCS) with 20kW module
|
Max. Output Current |
125A(CHAdeMO)/200A(CCS) |
Output Power Range(kW) |
60-160 |
Voltage Accuracy (%) |
± 1 |
Current Accuracy (%) |
± 1 |
User Interface & Control |
Display |
7 inch touch screen |
Push Buttons |
Emergency Stop |
User Authentication |
RFID system ISO / IEC14443A/B |
Display Information |
Charging process and status / Alarm and warning messages |
Communication |
External |
Ethernet/4G/3G |
Internal |
CANbus / RS485 |
Environmental |
Operating Temperature (°C) |
-30 ~ +50, power derating from 50 and above |
Humidity (%) |
5~95RH, non-condensing |
Altitude (m) |
≤2500 |
IP Level |
IP54 |
Cooling method |
Fan cooling |
Mechanica |
Weight(kg) |
420 ~ 465 |
Cable Length(m) |
5 |
Protection |
Input Protection |
OVP, OCP, OPP, OTP, UVP, Residual current detection, Surge protection, Cabinet-open detection (rear door) |
Output Protection |
SCP, OCP, OVP, LVP, OTP, Residual current detection |
Regulation |
Certificate |
IEC 61851-1:2017, IEC 61851-23, IEC 61851-24, IEC 61851-21-2
|
Safety |
CE,UL |
Charging Interface |
CHAdeMO 1.2, ISO15118, DIN 70121
|